analog/digitale Highend Data - Acquisition Card XADIO 8.0
 
 
Filtering

The conversion principle of the A/D converter (64-fold oversampling) results in an automatic filtering with a digital filter of at least the 8th order and a linear phase shift. The cut-off frequency changes automatically with the sampling rate (cutoff = 90 db by sampling rate /2)

Passband: 0.05 db Ripple

Cutt-Off Band : 96 db Attenuation

From the AD Converter manual.